Reduction of Operating Expenses and Generation of Additional Revenue by Using the Method of the Reagent Cleaning of the Sprinkler to Increase the Cooling Capacity and Efficiency of the Evaporative Cooling Tower
9/17/2026 2026 - #03 Nuclear power plants
Povarov V.P. Smorodinov E.V. Karandeeva N.V.
https://doi.org/10.26583/npe.2026.3.04
UDC: 628.1.17
The article provides a comparative analysis of reducing operating costs and generating additional revenue when using a mechanical and chemical method for removing contaminants from evaporative cooling towers to increase their efficiency and reliability using the example of measures taken as part of the scheduled preventive maintenance of power units № 1 NVNPP-2 and № 2 NVNPP-2 in 2025. The analysis method used was the calculation of the unit costs of repairs within the framework of the scheduled preventive maintenance, which differed in the ways of restoring the evaporative tower cooling capacity. According to the results of the analysis, it was found that the chemical cleaning of the central zone sprinkler, along with the replacement of the peripheral zone of the cooling tower, can significantly reduce the time and improve the quality of the evaporative cooling tower repairs, reaching the project values of the cooling depth of the circulating water at the condenser inlet during the hottest period of the year. The analysis, taking into account the realization of the capacity of its own production, proves the expediency of using a combined approach in implementing measures to improve the efficiency of the evaporative cooling tower, which is especially important for nuclear power plants on hard water sources.
References
- Ponomarenko V. S. Cooling towers of industrial and energy enterprises: reference manual. Moscow, Energoatomizdat Publ., 1998, 376 p. ISBN 5-283-00284-5 (in Russian).
- Fedyaev V.L., Mazo A.B., Morenko I.V., Gainullin R.F., Gainullina R.F. On the efficiency of industrial cooling towers. Energy problems. 2009;1-2:15–24. EDN: KYTTOX. URL: https://cyberleninka.ru/article/n/ob-effektivnosti-raboty-promyshlennyh-gradiren (accessed Jul. 03, 2026) (in Russian).
- Zenovich-Leshkevich-Olpinskiy Yu.A., Shiroglazova N.V., Zenovich-Leshkevich-Olpinskaya A.Yu. Improvement of Systems of Technical Water Supply with Cooling Towers for Heat Power Plants Technical and Economic Indicators Perfection. Part 2. ENERGETIKA. Proceedings of CIS higher education institutions and power engineering associations. 2016;59(4):362-375. DOI: https://doi.org/10.21122/1029-7448-2016-59-4-362-375 (in Russian).
- Badriev A.I., Sharifullin V.N. Analysis of the process in a tower cooling tower with low efficiency of its operation. Abstracts of the International Conference “Modern problems of thermophysics and Power Engineering”, October 9-11, 2017. Moscow, NRU “MEI” Publ., 2017, vol. 2, p. 57–58. URL: https://repository.kpfu.ru/?p_id=165679 (accessed Jul. 03, 2026) (in Russian).
- Tatarnikova N.A., Taktashev R.N., Ondar A.B., Gorin M.U., Hrushkov I.I. Improving the energy efficiency of TPP cooling systems with tower evaporative cooling towers. Energy saving – theory and practice. Proceedings of the Eleventh All-Russian Conference with International Participation, Moscow, October 10–14, 2022. Moscow, Limited Liability Company “Center of printing services “RADUGA” Publ., 2022, p. 26–29. EDN: XCLTHZ (in Russian).
- Galanin A.V., Karandeeva N.V., Vasilyeva S.Y. Use of Inhibitors to Prevent Oxidation in Cooling Systems of Nuclear Power Plants. Selection of the Optimal Water Chemistry Regime Using a Model Unit. Izvestiya vuzov. Yadernaya Energetika. 2025;1:96–112. EDN: LOLZNP. DOI: https://doi.org/10.26583/npe.2025.1.07 (in Russian).
- Povarov V.P., Vitkovsky S.L., Goncharov I.A., Galanin A.V., Kolyagina I.A., Shvarov V.A. Chemical cleaning of heat exchange equipment with Biorenex preparation. Energetik. 2015;5:14–15. EDN: TWVZBV (in Russian).
- Povarov V.P., Bakulin V.V., Karandeeva N.V. Experience in conducting reagent cleaning of the sprinkler to increase the cooling capacity and efficiency of the tower evaporative cooling tower. Global nuclear safety. 2025;15(3):43–56. DOI: https://doi.org/10.26583/gns-2025-03-05 (in Russian).
- Dautov R.G., Vilokhin S.A. Improving the efficiency of the cooling process in a cooling tower. Bulletin of Kazan Technological University. 2013;16(5):190–192. URL: https://cyberleninka.ru/article/n/povyshenie-effektivnosti-protsessa-ohlazhdeniya-v-gradirney (accessed Jul. 03, 2026) (in Russian).
- Lapteva E.A., Laptev A.G., Farrakhov M.I. Indicators of energy efficiency of cooling towers. Reliability and safety of power engineering. 2018;11(3):217–221. DOI: https://doi.org/10.24223/1999-5555-2018-11-3-217-221 (in Russian).
evaporative cooling towers sprinkler replacement hydrochemical cleaning combined approach scheduled preventive maintenance economic effect cost reduction
Link for citing the article: Povarov V.P., Smorodinov E.V., Karandeeva N.V. Reduction of Operating Expenses and Generation of Additional Revenue by Using the Method of the Reagent Cleaning of the Sprinkler to Increase the Cooling Capacity and Efficiency of the Evaporative Cooling Tower. Izvestiya vuzov. Yadernaya Energetika. 2026, no. 3, pp. 52-61; DOI: https://doi.org/10.26583/npe.2026.3.04 (in Russian).