The study of temperature influence on the performance of conductometric hydrogen sensor element based on PdAg alloy
12/29/2013 2013 - #04 Global safety, reliability and diagnostics of nuclear power installations
Skomorokhov A.N. Shelemetyev V.M. Storozhenko A.N. Skomorokhova S.N. Sitnikov I.V.
https://doi.org/10.26583/npe.2013.4.06
UDC: 53.082.731:543.272.2
Temperature influence on such characteristics of the conductometric hydrogen sensor elements response time and magnitude of variation of the electric resistance in the temperature range from 180 up to 310°С has been investigated. Type of functional dependence of variation of the electric resistance in dependence from hydrogen concentration at various temperatures was determined.
Link for citing the article: Skomorokhov A.N., Shelemetyev V.M., Storozhenko A.N., Skomorokhova S.N., Sitnikov I.V. The study of temperature influence on the performance of conductometric hydrogen sensor element based on PdAg alloy. Izvestiya vuzov. Yadernaya Energetika. 2013, no. 4, pp. 51-56; DOI: https://doi.org/10.26583/npe.2013.4.06 (in Russian).