Efficiency Criteria for High Reliability Measured Systems Structures
5/29/2012 2012 - #01 Global safety, reliability and diagnostics of nuclear power installations
https://doi.org/10.26583/npe.2012.1.08
UDC: 621.039.58
To develop high reliability measured systems usually there are used procedures of structural redundancy. To estimate efficiency of such structures there is developed criteria to compare different systems. So it is possible to develop more exact system by inspection of redundant system data unit stochastic characteristics in according with developed criteria.
Link for citing the article: Salnikov N.L. Efficiency Criteria for High Reliability Measured Systems Structures. Izvestiya vuzov. Yadernaya Energetika. 2012, no. 1, pp. 66-70; DOI: https://doi.org/10.26583/npe.2012.1.08 (in Russian).